'************************* WEBASTO *************************

'   calculates how intensively webasto have to work in comparsion to different temperatures
[newcurve]
standheizung_x_temperature_difference

[pnt]
-15
0.45

[pnt]
0
0.15

[pnt]
10
0.1

'   time to start
[const]
standheizung_vorlauf
10

'   minimum heat time
[const]
standheizung_nachlauf
60

[const]
standheizung_minlauf
5

'   minimal water temperature
[const]
standheizung_brenner_t_ein
72

'   water temperature after which webasto switches off
[const]
standheizung_brenner_t_aus
82

'   automatic webasto run 
[const]
standheizung_automatic
1

'   automatic webasto run - minimal external temperature threshold
[const]
standheizung_auto_min_temp
2

'************************* HEATING *************************

'   internal values
[const]
cabinair_A_cabinheater
0.12

[const]
cabinair_A_frontheater
0.04

[const]
cabinair_cvm
93000

[const]
cabinair_T_passenger
37

[const]
cabinair_Vrate_passenger
0.00011

[const]
cabinair_V
90

[const]
cabinair_A_driverwindow
0.03

[const]
cabinair_A_perdoor
0.15

[const]
cabinair_A_perwindow
0.03

[const]
cabinair_A_perdachluk
0.055

[const]
cabinair_windowdoor_minkmh
4

[const]
cabinair_windowdoor_effectivity
1.1

[const]
cabinair_Qrate_envir_factor
70

[const]
cabinair_Qrate_engine_factor
15

[const]
cabinair_cv
717
J/kgK